Power Inverter

SAFETY INSTRUCTIONS

To ensure reliable service your power inverter must be 
installed and used properly.
Read and understand the installation and operating 
thoroughly prior to installation and use. Pay particular 
attention to the WARNING and CAUTION statements 
in this manual.

CAUTION statements advise against certain condi-
tions and practices that may result in damage to your 
inverter.
WARNING statements identify the conditions or prac-
tices that may result in injury or death.
PLEASE READ ALL THE INSTRUCTIONS BEFORE 
USING THIS POWER INVERTER.

WARNING:

To reduce this risk of 

fi

 re, electric shock, explosion or 

injury:

  Do not connect to AC distribution wiring.

  Always disconnect appliances from the inverter and 

turn the inverter off before working the appliance. 
Multiple outlet power strips with switches and power 
switches and circuit breakers only interrupt power 
to the “live” socket terminals. The neutral terminals 
remain powered with respect to the earth terminals.

  Do not make any electrical connections or discon-

nections in areas designated as IGNITION PRO-
TECTED including DC cigarette lighter type plug 
connections and ring terminal connections. Always 
disconnect appliance from the inverter before re-
moving the inverter power source.

  Do not obstruct or block the air vents on the invert-

er.

  The inverter is not a toy, keeps away from children.

CAUTION:

  Do not use with positive earth electrical systems (the 

majority of modern vehicles are negative earth). A 
reverse polarity connection will result in a blown fuse 
and may cause permanent damage to the inverter.

  The inverter will not operate high wattage applianc-

es or equipment that produces heat, such as dryers, 
microwave ovens and toasters.

  Earthing the neutral will cause the inverter to shut 

down.

  Do not operate the inverter if it is wet. Water and 

electric do not mix.

  Do not install the inverter in the engine compart-

ment, the inverter must be used in a well ventilated 
position.

  This inverter is not tested for use with medical equip-

ment.

IMPORTANT CABLE INFORMATION

Substantial power loss and reduced battery operating 
time result from inverters installed with cables that are 
not able to supply full power. Symptoms of low battery 
power can result from cables that are either excessively 
long or of an insuf

fi

 cient gauge. Marine installations are 

subjected to vibration and stresses that exceed those 
of other mobile installations, therefore the installer/op-
erator should be especially aware of the requirements 
to maintain secure, tight water resistant electrical con-
nections and provide for strain relief for DC cables and 
appliance wiring. Cable insulation must be the appro-
priate type for the environment.

INTRODUCTION

The inverter supplies continuous power in the form of 
one household type socket. The inverter has enough 
power to run almost any household or electronic appli-
ance. Safety features include automatic shut down and 
a low battery alarm to prevent damage to your battery.

CONTROLS, INDICATORS AND CONNEC-
TORS

The front panel of the inverter provides two LED indica-
tors. The green LED indicator shows the unit is working 
correctly when lit. The red LED indicator shows inverter 
shut down from overload, over voltage or over temper-
ature. The inverter is 

fi

 tted with an on/off switch, the on/

off switch is also used to force reset the inverter circuits 
in case of overload, over voltage or over temperature. 
Power is supplied through the three pin AC plug and 
DC input power is supplied via the rear panel.

HOW INVERTERS WORK

Principle of operation 

The inverter converts low voltage DC (direct current) 
from a battery or other power source to standard AC 
(alternating current) household power. The inverter 
converts power in two stages. The 

fi

 rst stage is a DC to 

DC conversion process that raises low voltage DC from 
the inverter input to high volt DC. The second stage is 
the actual inverter stage that converts the high DC into 
AC power.
The DC to DC converter stage uses modern high 
frequency power conversion techniques that have re-
placed bulky transformers found in less technologically 
advanced models. The inverter uses advanced MOS-
FET transistors in a full bridge con

fi

 guration,  which 

ensures excellent overload capabilities and allows the 
inverter to operate reactive loads such as small induc-
tion motors.

The output waveform

The AC output waveform is known as a “modi

fi

 ed sine 

wave”. It is a waveform that has characteristics similar 
to the sine wave shape of standard household power. 
This type of switching power is suitable for most AC 
load, including linear and switching power supplies 
used in electronic equipment, transformers and mo-
tors.