USER’S MANUAL
7. SPECIFICATIONS AND INDICATION TABLE
425, 650 & 800 Specifications
24
Specification
Pro 425
Pro 650, Pro 800
Capacity rating
425 VA
650 VA; 800 VA
Nominal input volt.
200, 220, 230, 240 user adjustable
Nominal input freq.
50. 60 Hz auto sensing, user adjustable default
Acceptable input volt.
0 J 33% over the nominal input voltage
On line input freq. limits
+/J 5% over the nominal input freq.
Output voltage
+/J 15% from the nominal input volt
Output frequency
+/J 1 Hz from the nominal input freq.
Output wave form
PWM. stepped wave approximation to sine wave
Continuous output capacity
425 VA. 3J5 min.
650 VA; 800 VA. 3J5 min.
Typical back up time
15J22 min.
30J40 min.
Transfer time
2 ms typical, 4 ms max.
Maximum load
425 VA/280 W
650 VA/400 W; 800 VA/500 W
Noise filter
Full time EMI/RFl filtering, 100 kHz to 10 MHz
Surge energy rating
320 J
480 J
Surge current capability
4500 A
6500 A
Surge response time
0 ns normal mode, <5 ns common mode
Surge voltage let through
0.7% subject to IEEE 587 Cat. A 6 kV test
Processor
RISC based micro processor
Detection
power source RMS value, locked phase, no load power saving, output load, opeatJ
ing temperature, bad battery, battery condition & system fault
Protection
overcurrent, shortJcircuit, overload, lightening, surge, noise, sags, brownout,
blackout, input breaker, modem & 10BaseT
Battery type
sealed and leak proof maintenance free leadJacid
Alarm signals
Audible signals,
45 dBA at 1 meter
Battery capacity
12 V, 7 Ah
12 V, 11 Ah
Recharging time
4 hours typical, 10 hours max.
Communication port
RS232, standard