ADJ Products, LLC  -  www.adj.com  - Inno Spot LED Instruction Manual Page 6

ADJ Products, LLC  -  www.adj.com  - Inno Spot LED Instruction Manual Page 5

Power Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your ADJ Inno Spot 

LED. The ADJ Inno Spot LED is available in a switchable 120v and 

220v  version.  Because  line  voltage  may  vary  from  venue  to  venue, 

you should be sure your unit voltage matches the wall outlet voltage 

before attempting to operate you fixture.  Also be sure to only use the 

included I.E.C. power cable supplied with the unit, this cable matches 

the voltage and current requirements of the unit.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 

communication between intelligent fixtures and controllers. A DMX 

controller sends DMX data instructions from the controller to the fix-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models 

of different manufactures to be linked together and operate from a 

single controller, as long  as all  fixtures and  the  controller  are DMX 

compliant.  To ensure proper DMX data transmission, when using 

several DMX fixtures try to use the shortest cable path possible. The 

order in which fixtures are connected in a DMX line does not influence 

the DMX addressing. For example; a fixture assigned a DMX address 

of 1 may be placed anywhere in a DMX line, at the beginning, at the 

end, or anywhere in the middle. Therefore, the first fixture controlled 

by the controller could be the last fixture in the chain. When a fixture 

is assigned a DMX address of 1, the DMX controller knows to send 

DATA assigned to address 1 to that unit, no matter where it is located 

in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX 

and Master/Slave Operation): 

The Inno Spot LED 

can be controlled via DMX-512 protocol. The Inno 

Spot LED is a ten channel DMX unit. The DMX 

address is set electronically using the controls on 

the front panel of the unit. Your unit and your DMX 

controller require a approved DMX-512 110 Ohm 

Data cable for data input and data output (Figure 

1). We recommend Accu-Cable DMX cables. If you are making your 

 Inno Spot LED 

                                                     Set Up

Figure 1

own cables, be sure to use standard 110-120 Ohm shielded cable (This 

cable may be purchased at almost all professional sound and lighting 

stores). Your cables should be made with a male and female XLR con-

nector on either end of the cable. Also remember that DMX cable must 

be daisy chained and cannot be split.

 Inno Spot LED 

 

 

                                 Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4


Что удобнее для чтения книг?

Планшет
Электронная книга
Смартфон
Книга в бумажном переплёте
Не читаю книг

QR код manualbase.ru
©  2010- ManualBase.ru