Install the hood away from sources of electromagnetic waves, as these could affect the correct operation of the electronic system. 

 

Maximum operating distance: 5 metres. The maximum operating distance could be less than 5 metres in case of electromagnetic 
interference by other equipment. 

 

Light pushbutton on remote control:  light on/off. 

 

– and + pushbutton: increase/decrease speed (to start the motor press either the + or the – pushbutton). 

 

Timer pushbutton: see instructions below. 

 

Timer and ‘filter clogged’ alarm pushbutton 

 

- This function allows the automatic turning off of the hood after running for 15 minutes at the speed previously set (the pushbutton 
shows a flickering light). 

 

- After about 30 hours of running the pushbutton indicates the need for washing the metal filters (the pushbutton shows a solid red 
light). To disable the alarm press the pushbutton for a few seconds until the red light turns off. Then turn the hood off and on again 
to check that the alarm has disappeared.

3.   ELECTRONIC CONTROL PANEL

  

1: Timer/Alarm 

filters

 

The steady RED light 

indicates that the fat filter alarm is activated (after 30 hours), to deactivate this alarm and zero the meters, 

maintain the Key pressed for 3 seconds.

 

Flashing RED light

 indicates that the timer function is activated. This function can only be activated if the motor is activated and run-

ning at any velocity when the Key is pressed (either prolonged or not). This function will cause the automatic switch-off of the hood 
after 15 minutes.

 

With the Timer function activated, the hood can be switched-off by the operator in any case and the function will be deactivated. 

 

The Timer function remains associated to a velocity. A change in the velocity, with the Timer function activated, will deactivate it.

2: 1st 

Velocity

 When 

the 

LED is switched-off

, non-prolonged pressing of the key will switch-on the hood at the 1st velocity and illuminate the re-

spective LED. The function will switch-on when the Key is released.

 When 

the 

LED is switched-off and another velocity is activated

, pressing the Key will imply selection of the 1st velocity, switching-on 

of the respective LED and switching-off of the LED associated with the velocity that was previously selected.

 When 

the

 LED is on, pressing 

the Key will imply the switching-off the LED and MOTOR.

 When 

the 

LED is switched-off, prolonged pressing

 (at least 3 seconds) of the Key will cause activation of the recirculation function. 

During the recirculation function (with a duration of 24 hours), the 

LED will flash

. From the activation of this function, the hood will 

remain switched-on for one hour at the 1st velocity, after which it will switch-off for 3 hours and then reactivate for another hour. 
These cycles are repeated until the timeout. 

 

With this function activated, the other functions cannot be selected. To remove this function, keep Key 2 pressed for at least 3 sec-
onds.

3: 2nd 

Velocity

 When 

the 

LED is switched-off and another velocity activated

, pressing the Key (either prolonged or not) will imply the selection of 

the 2nd velocity, switching-on of the respective LED and switching-off of the LED associated with the velocity that was previously 
selected.

 When 

the 

LED is switched-off and no velocity activated

, pressing the Key will have no effect.

 When 

the 

LED is switched-on, pressing the Key 3

 will have no effect.

 

To switch the hood off, it will be necessary to firstly select the 1st velocity and then repress the same Key. 

4: 3rd 

Velocity

 When 

the 

LED is switched-off and another velocity activated

, pressing the Key (either prolonged or not) implies the selection of 

the 3rd velocity, the switching-on of the respective LED and switching-off of the LED associated to the velocity that was previously 
selected.

 When 

the 

LED is switched-off and no velocity activated

, pressing the Key will have no effect.

 When 

the LED is switched-on, pressing the Key 4

 will have no effect.

 

To switch the hood off, it will be necessary to firstly select the 1st velocity and then repress the same Key.

5: 4th Velocity

 When 

the 

LED is switched-off and another velocity activated

, pressing the Key (either prolonged or not) implies the selection of the 

4th velocity, switching-on of the respective LED and switching-off of the LED associated to the velocity that was previously selected.

 When 

the 

LED is switched-off and no velocity activated

, pressing the Key will have no effect.

 When 

the 

LED is switched-on, pressing the key 5

 will have no effect.

 

The forth velocity must remain on for a maximum of 7 minutes, after which, one must return to the third.

 

To switch the hood off, it will be necessary to firstly select the 1st velocity and then repress the same key.

6:  Light - Remote Binding
 Light: 

Briefly pressing key T6 will turn the light on and off. The T6 key will light up if the light is on.

 

Remote Binding (optional): 

With motor and light turned off, applying prolonged pressure on the T6 key will activate remote binding 

mode. The T6 Key will flash for a maximum of 10 seconds.  During flashing, at least one radio control key must be pressed.  The func-
tion will deactivate upon completion of the 10 seconds, or earlier if a compatible remote control is detected.

Key pressure management:
 

Prolonged pressure =

 finger pressed on key for at least 3 seconds, the function activates during pressure.

 

Non-prolonged pressure =

 finger pressed on key for less than 3 seconds, the function activates upon its release.

 

Radio control (optional):

 Place the device far from sources of electromagnetic waves which could interfere with the range hood’s 

electronic functions

 

Maximum operating distance 4 metres.  This distance may vary in defect based on electromagnetic interference of other devices. 