THERMEX TitaniumHeat 70 V Slim инструкция по эксплуатации онлайн - страница 22


Инструкция THERMEX TitaniumHeat 70 V Slim для устройства водонагреватель накопительный содержит страницы на русском языке.

Размер файла: 1.03 MB. Состоит из 52 стр.


Вы можете скачать pdf файл этой инструкции: Скачать PDF


Предыдущая
Следующая
background image

To carry out maintenance and replace the magnesium anode, one shall perform the following 
steps:

Power off the EWH;

џ

Allow hot water to cool down or use it through a mixer;

џ

Block the flow of cold water into the EWH;

џ

Unscrew the relief valve or open the drain valve;

џ

Put the rubber hose on the cold water inlet pipe or on the drain valve by directing its second end into 

џ

the sewage system;
Open the hot water faucet on the mixer;

џ

Drain the water from the EWH through the cold water inlet or drain valve;

џ

Remove the protective cover, disconnect the wires, unscrew and remove the removable flange 

џ

from the casing; 
Replace  the  magnesium  anode,  clean  the  THE  from  the  scale,  if  necessary,  and  remove  the 

џ

sediment; 
Perform the assembly, fill the EWH with water and switch on power supply.

џ

When  carrying  out  the  EWH  maintenance  using  the  resources  of  a  specialized  organization,  a 
corresponding mark shall be made in the warranty certificate with the stamp of the organization that 
carried  out  the  maintenance.  When  the  magnesium  anode  is  replaced  by  the  customer,  a  sales 
receipt for the purchase of the magnesium anode shall be attached to this EWH manual.

Possible malfunctions and remedies

In case of malfunction in the product operation, it is necessary to disconnect it from the power supply 
network and shut off the water supply.

Failure

The pressure of hot 
water from the EWH 
has decreased. Cold 
water pressure has 
not changed

Remedy

Remove the valve and rinse it 
with water

Possible Reason

Clogging of the relief valve 
inlet opening

Heating time has 
increased

THE is covered with scale 
crust

Remove the THE and descale it

The voltage in the power 
supply network has decreased

Contact the organization 
responsible for the maintenance 
of the power supply network

The valve 

24

 (

Fig.1, 2

) is not 

closed or failed

Close or replace the valve 

24

 (

Fig.1, 2

)

EWH works, but does 
not heat water

23

When connecting the EWH in places not equipped with running water, it is acceptable to supply water 
to the EWH from the auxiliary reservoir using a pump station, or from a reservoir placed at a height of 
not less than 5 meters from the top of the EWH.

Connection to the power supply network

Before switching on the heater, make sure that its parameters are in line with the technical 
characteristics of the water heater.

CAUTION! Before switching on the power supply, make sure that the EWH is filled with 
water!

The water heater shall be grounded to ensure its safe operation.

The EWH is equipped with a regular power cord with or without a europlug and a residual current 
device (optional). The electrical socket shall have a grounding terminal with a ground wire supplied to 
it and be located in a place protected from moisture or meet the requirements not lower than IPX4.

It is important to constantly monitor the EWH after the initial powering. In case of any parameter 
mismatch  (heating,  temperature,  indication,  thermostat  failure),  contact  the  maintenance 
department.

Maintenance

Periodic maintenance and timely replacement of the magnesium anode are indispensable conditions 
for the long-term operation of the EWH. Failure to comply with these requirements is the basis for 
withdrawing the EWH from warranty service.

 Maintenance and replacement of the magnesium 

anode are not included in the manufacturer's and the seller's warranty liabilities.

During maintenance, the check is performed with respect to the condition of the magnesium anode 
and  the  presence  of  scale  on  the  THE.  Simultaneously,  the  sediment  is  removed,  which  may 
accumulate at the bottom of the EWH.

The magnesium anode shall be replaced at least once a year. If water contains a large number of 
chemical impurities, the magnesium anode shall be replaced every six months. The formation of 
scale on the heating element may lead to its failure, which is not a warranty case, and its replacement 
is not included in the manufacturer's and the seller's warranty liabilities.

If there is some scale on the heating element, it can be removed with the use of descaling agents or 
mechanically.  When  removing  sediment  from  the  EWH,  do  not  apply  excessive  force  and  use 
abrasive cleaners to avoid damaging the protective coating of the inner tank.

The first maintenance procedure is particularly important, because the intensity of the formation of 
scale and sediment and the consumption of magnesium anode serve as the grounds for determining 
the timing of subsequent maintenance, which in turn provides an opportunity to extend the EWH life 
cycle. If the above requirements are not fulfilled, the EWH life cycle is shortened, the probability of 
EWH failure increases, and the warranty liabilities are terminated.

22

EN

EN


Что удобнее для чтения книг?

Планшет
Электронная книга
Смартфон
Книга в бумажном переплёте
Не читаю книг

QR код manualbase.ru
©  2010- ManualBase.ru