"Cold Start" function

• 

It is possible to turn on the UPS without connection to the mains using the "Cold Start" function.

Before this, turn off the connected consuming devices using the respective switches. Press button 

d

 to turn on the UPS. In this case, indicator 

c

 will light up, an acoustic signal will be generated and 

indicator 

b

 will light up. Output voltage will be generated on the outlets 

g

. Turn on the consuming 

devices in input power descending order.

Note. Application of the "Cold Start" function is not recommended under high load.

Acoustic alarms and protection

• 

During transition to the battery mode (at the loss of mains power supply) the UPS generates a 

short acoustic signal. Indicator 

b

 lights up. Further, under operation in the battery mode, the acous-

tic signals are generated every 5 seconds until the UPS is shut down. 

• 

Under high load (110%), the UPS generates frequent intermittent warning signals during 30 seconds. 

Then the load is automatically released.

Important! The UPS is designed for power supply of the PC and monitor only. Avoid connec-

tion of such hardware peripherals as laser printers and other devices with significant input 

power. Remember that in case of the mains power loss, the duration of power supply from 

the battery depends on the input power of the equipment connected and the battery con-

dition. In this situation please save all the opened documents and shut down the computer 

and then the UPS.

Note:

• If the UPS is not operated for a long period of time, disconnect it from the mains.

Charge the battery every three months by connecting the UPS to the power supply mains 

for  12  hours.  We  recommend  to  read  the  manufacturer’s  manual  for  the  proper  mainte-

nance of the battery. 

Storage conditions

• 

The temperature range and humidity in the premise supposed to be used for installation of the  

UPS

 shall comply with the set values specified in the "Technical Specifications" Table.

• 

Store the UPS together with a fully recharged battery.

• 

The storage conditions for batteries shall comply with the battery manufacturer requirements.

Input fuse replacement

In order to replace the input fuse dis-

connect the power cable (Fig.3) and 

carefully open the fuse box (Fig.4).

The  nearest  fuse  in  the  box  is  the 

back-up one, the most distant is the 

main  one.  Remove  firstly  the  main 

(most  distant)  fuse  and  check  the 

conductor  for  integrity.  If  required, 

replace with the back-up one (in the 

nearest  tray)  or  with  the  similar  one 

(6.3A/250V).