Eng
SMART L 1000/2000/3000
NOTE:
This manual is provided «as it is», without any warranties, either express or implied. The supplier and its distributors are not liable
for any error, correctness, accuracy and reliability of the information, either express or implied, herein contained.
The manufacturer and its distributor are not liable for any direct, indirect, incidental, consequential, loss of business profits, punitive or
special damages, even if it and its suppliers have been advised of the possibility of such damages.
This manual is subject to changes without notice.
19
Specifications/Model
Smart L 1000
Smart L 2000
Smart L 3000
Output (Battery Operation)
Voltage
230 V ± 3 %
Frequency
± 1 % (Free Running)
Frequency Stability
± 0,5 Hz
Wave Form
Sine wave
Voltage T.H.D
<10 % Full RCD Load, <5 % Full Linear Load
Transient Response (ms)
10 % R Load 0 % to100 % and 100 % to 0 %,100 ms
Over Load Capacity
<110 % continuously; 110–125 % Warning 30 sec, Transfer to Fault; >125 % Transfer to Fault
Efficiency on Battery Mode
> 80 %
Transfer Time
0 ms (Zero Transfer)
Continuous output capaci'
ty for full/half loading
9,6/25 minutes
6/17 minutes
5/14 minutes
Battery System
Battery Type
Sealed and leak proof maintenance free lead acid
Battery Capacity
12 V, 7 А • h (4)
12 V, 7 А • h (6)
12 V, 7 А • h (10)
Recharging Time
4 hours typical (battery voltage >85 %), 10 hours max (battery voltage >90 %), float change
Mechanical
Physical Dimension
190 x 255 x 467 mm
190 x 255 x 532 mm
225 x 480 x 470 mm
Weight
21.3 kg
29 kg
52.5 kg