10. SPECIFICATIONS
Specifications/Model
Smart L 1000
Smart L 2000
Smart L 3000
Maximum load
1000 VA/700 W
2000 VA/1400 W
3000 VA/2100 W
Processor
RISC based micro processor
Detection
Power source RMS value, locked phase, output load, operation temperature,
battery condition & system fault
Protection
Over'current, short circuit, latching shutdown, overload, brownout, blackout, input breaker
Surge energy rating
480 J
Communication Port
RS'232 standard
Interface connection sup'
port
UPSilon 2000 for Novell NetWare, Windows 95/98, Windows NT, Windows ME, Windows 2000,
Windows XP or other Windows Operation Systems, Linux and Free BSD (Basic Version)
Indicators
LED's ' AC mode, Charging mode & System fault LCD ' AC normal, Battery mode, Bypass,
Abnormal, Charging overload, Load status, Battery capacity, Input of Voltage/Frequency,
Output of Voltage/Frequency
Audible Noise
< 50 dBA @ 1m
Intput socket
IEC 320
Screw connection
Output socket
4 x IEC320
Altitude
0~2000 m up to 40 °C, 3000m up to 35 °C
Agency Approval
UL. cUL, FCC, [CE,TUV] RusТест
Input (Non Battery Operation)
Voltage Range default
160'270 V
Frequency Range
47–53 at 50 Hz, 57–63 at 60 Hz
Output (Non Battery Operation)
Voltage Range default
230 V ± 3 %
Wave Form
Sine wave
Over Load Capacity
<100–110 % Warning; 110–125 %, Warning 30sec, Transfer to Bypass; >125 % Transfer to Bypass