INSTRUCTION MANUAL

 

IMPORTANT NOTE:

BEFORE  USING  THE  EQUIPMENT  READ  THE 

INSTRUCTION MANUAL CAREFULLY!
DESCRIPTION OF THE COOLING UNIT

This liquid cooling unit must only be used for cooling MIG/

MAG and TIG water welding torches.

TECHNICAL DATA

Data plate (TAB. 1)

The  main  data  relating  to  use  and  performance  of  the 

cooling unit are summarised on the rating plate and have 

the following meanings:

-  P

1 l/min

: cooling power at a refrigerant flow rate of 1 l/

min and an ambient temperature of 25°C.

-  symbol for system with liquid refrigerant. 

-  symbol for main power supply. 

-  U

1

: Alternating voltage and frequency of cooling unit 

power supply (allowed limits ± 10% ).

-  symbols  referring  to  safety  standards:  before 

using  the  apparatus  read  the  instruction  handbook 

carefully!

-  serial  number  for  identifying  the  coolant  unit 

(essential when asking for servicing or spare parts, 

or finding the origin of the product). 

-  EUROPEAN  standard  of  reference  for  safety  and 

construction of cooling systems for arc welding. 

-  I

1 max

: maximum current absorbed by the line.

-  Protection rating of enclosure. 

10 

-  P

max

: maximum pressure.

NOTE:

 The rating plate shown is an example to show the 

meaning of the symbols and numbers; the exact values of 

the technical properties of the cooling unit should be read 

directly on the rating plate of the unit itself.

INSTALLATION, SAFETY AND OPERATIONS

WARNING! 

ALL 

THE 

INSTALLATION 

OPERATIONS AND ELECTRIC CONNECTIONS 

SHOULD  BE  CARRIED  OUT  WITH  THE 

EQUIPMENT  TURNED  OFF  AND  DISCONNECTED 

FROM THE POWER SUPPLY. EXPERT AND QUALIFIED 

PERSONNEL  MUST  CARRY  OUT  THE  ELECTRIC 

CONNECTIONS.

LIFTING THE EQUIPMENT

The cooling unit described in this manual is not fitted with 

lifting systems.

POSITIONING THE EQUIPMENT

The  installation  position  for  the  cooling  unit  must  be 

chosen to ensure that the cooling air inlet and outlets are 

not blocked in any way (forced fan circulation, if fitted); at 

the same time, ensure that no conductive dust, corrosive 

vapours, humidity, etc. could be sucked in.

A free space of at least 250 mm should be left around 

the cooling unit.

WARNING!  Position  the  equipment  on  a  flat 

surface  adequate  to  support  the  weight,  to 

avoid  it  tipping  over  or  making  dangerous 

movements.
POWER SUPPLY (ELECTRICAL CONNECTION)

The  cooling  unit  must  be  connected  to  the  welding 

machine using the cable provided 

(FIG.B)

.

CONNECTION TO THE WELDING MACHINE 

-

 

Connect

 

the cable supplied 

(FIG. B)

 to the cooling unit, 

using the dedicated connector (5-pin female).

-  Connect the connector at the other end of the cable 

(5-pin male) to the corresponding outlet on the back 

panel of the welding machine.

OPERATIONS

ATTENTION! THE TANK CAN ONLY BE FILLED 

AFTER  HAVING  SWITCHED  OFF  THE 

APPARATUS AND DISCONNECTED IT FROM 

THE MAINS.

ONLY USE DEMINERALISED WATER.

IF WORKING WITH TEMPERATURES OF BELOW 2 °C, 

WE ADVISE USING ANTIFREEZE WITH AN ETHYLENE 

BASE, OR A MIXTURE OF DEMINERALISED WATER 

AND ETHYLENE GLYCOL.

DO NOT FOR ANY REASON USE POLYPROPYLENE 

BASED ANTIFREEZE.

1  -

  Fill the tank through the filler: tank CAPACITY = 8 l; 

take care not to let the water overflow when the tank 

is full.

2  - 

Close the cap on the tank.

3  -

  Connect  the  outer  piping  for  the  cooling  to  the 

relative fittings, taking care of the following specific 

instructions:

    - 

 : WATER DELIVERY (Cold water)

    - 

 : WATER RETURN (Hot water)

   

Front connections

    In order to use these fittings it is necessary for the 

”cap”  provided 

(FIG.  E)

  to  be  inserted  in  the  rear 

delivery connection 

(FIG. F)

.

   

Rear connections

    These  are  to  be  used  for  the  fitting  of  water  pipes 

present  in  the  RA  cables  bundle  of  the  outer  draft 

(where  present),  but  also  for  the  fitting  of  the  TIG 

RA  gun’s  water  piping,  by  interposing  the  adapter 

available as an accessory 

(Fig. C)

.

4  -

  Make the connection to the power outlet and turn the 

switch to position ”I”.  The cooling unit will then start 

operation, circulating the water in the torch.

5  -

  If  the  cooling  unit  is  connected  to  the  welding 

machine,  the  switch  is  not  used  because  power 

supply control is managed by the welding machine 

Cod.953460

GB

 ............pag. 01

I

.................pag. 02

F

 ...............pag. 04

D

 ...............pag. 06

E

 ...............

pag. 08

P

 ...............pag. 09

NL

 ............. pag. 11

DK

 ............pag. 13

SF

 .............pag. 15 

N

 ...............pag. 16

S

 ...............

pag. 18

GR

 ............pag. 20

RU

 ............pag. 21

H

 ...............pag. 23

RO

 ............pag. 25

PL

 .............pag. 27

CZ

 .............pag. 29

SK

.............pag. 30

SI

 ..............pag. 32

HR/SCG

 ....pag. 34 

LT

 .............pag. 35

EE

....... ......pag. 37

LV

 .............

pag. 38

BG

 ............pag. 40


Что удобнее для чтения книг?

Планшет
Электронная книга
Смартфон
Книга в бумажном переплёте
Не читаю книг

QR код manualbase.ru
©  2010- ManualBase.ru