INSTRUCTION MANUAL FOR INSTALLATION, MAINTENANCE AND USE
Rev-09
PM.IE
8-9-1-R-GN-DU-GB-09
9
ELECTRIC KETTLES INDIRECT
“PM8-9IE..A” “PM1IE..A” “PMRIE..A” “PM9IE..GN”
2
POSITIONING, INSTALLATION AND MAINTENANCE
2.1
POSITIONING
Remove all the packaging and check that the appliance is in perfect conditions. In case of visible damage,
do not connect the appliance and notify the sales point immediately.
Remove the PVC protection from the panels.
Dispose of packaging according to regulations. Generally material is divided according to composition and
should be delivered to the waste disposal service.
There are no special instructions regarding distances from other appliances or walls, however it is
advisable to maintain a sufficient distance to allow any servicing operations to be performed. In the event
the appliance should be installed in direct contact with inflammable walls, it is advisable to fit suitable heat
insulation.
The appliance must stand level. Small differences in level can be eliminated by screwing or unscrewing
the adjustable feet: A significantly uneven or sloping stance can affect the operation of the appliance
adversely.
2.2
INSTALLATION
Warning! : Only qualified technicians must perform the installation, maintenance and test of the
appliance.
Warning! :
Before connecting any parts of the appliance to supplies, make sure that the latter is
equivalent the requirements stated in the technical data plate, if the appliance has been designed for
these supplies.
2.2.1
ELECTRICAL CONNECTIONS AND EQUIPOTENTIAL BONDING
Warning! :
The appliance is supplied to operate according to the power supply indicated on the
data plate.
As mentioned, the appliance must be connected to the power supply by way of a multiple pole main
isolating switch and protection device that must be proportioned to the power of the appliance (1 mA per
kW of rated power).
The earthing system must be efficient.
As this appliance is type X equipment (delivery without power cable and plug), the cable and other
hardware needed to make the connection to the electrical power supply must be provided by the installer.
The power cable shall be of the kind described in the paragraph “Technical data" and shall be resistant to
oil.
The power terminal board can be reached by removing the lower front panel (unloose the screws). The
cable fastener is on the lower right-hand side.
The cable must be fed in from beneath the clamp. The individual wires are then fastened to the
corresponding terminals of the terminal board. The earth wire must be longer than the other wires, so that
in the event of the cable being jerked or the clamp broken, the live wires will disconnect first. Lock the cord
fastener.
The appliance must incorporate an equipotential system.