GB

Installation

!

 Before operating your new appliance please read this instruction booklet 

carefully. It contains important information for safe use, installation and care 

of the appliance.

!

 Please keep these operating instructions for future reference. Pass them on 

to possible new owners of the appliance.

Positioning

!

 Keep packaging material out of the reach of children. It can become a choking 

or suffocation hazard (see Precautions and tips).

!

 The appliance must be installed by a qualified professional according to the 

instructions provided. Incorrect installation may cause harm to people and 

animals or may damage property.

!

 This unit may be installed and used only in permanently ventilated rooms 

in accordance with current national regulations. The following requirements 

must be observed:

•  The room must be equipped with an air extraction system that expels 

any combustion fumes. This may consist of a hood or an electric fan that 

automatically starts each time the appliance is switched on.

In a chimney stack or branched flue. 

(exclusively for cooking appliances)

Directly to 

the Outside

•  The room must also allow proper air circulation, as air is needed for 

combustion to occur normally. The flow of air must not be less than 2 m

3

/h 

per kW of installed power. 

The air circulation system may take air directly 

from the outside by means of a pipe with an 

inner cross section of  at least 100 cm

2

; the 

opening must not be vulnerable to any type 

of blockages.

The system can also provide the air needed for 

combustion indirectly, i.e. from adjacent rooms 

fitted with air circulation tubes as described 

above. However, these rooms must not be 

communal rooms, bedrooms or rooms that 

may present a fire hazard.

•  Intensive and prolonged use of the appliance may necessitate 

supplemental ventilation, e.g. opening a window or increasing the power 

of the air intake system (if present).

•  Liquid petroleum gas sinks to the floor as it is heavier than air. Therefore, 

rooms containing LPG cylinders must also be equipped with vents to allow 

gas to escape in the event of a leak. As a result LPG cylinders, whether 

partially or completely full, must not be installed or stored in rooms or 

storage areas that are below ground level (cellars, etc.). It is advisable to 

keep only the cylinder being used in the room, positioned so that it is not 

subject to heat produced by external sources (ovens, fireplaces, stoves, 

etc. ) which could raise the temperature of the cylinder above 50°C.

A

Examples of 
ventilation holes 
for comburant air.

Enlarging the ventilation slot

between window and floor.

Adjacent

Room

Room to be

Vented

Fitting the appliance

The following precautions must be taken when installing the hob:

•  Kitchen cabinets adjacent to the appliance and taller than the top of the 

hob must be at least 200 mm from the edge of the hob.

•  Hoods must be installed according to their relative installation instruction 

manuals and at a minimum distance of 650 mm from the hob (see figure).

•  Place the wall cabinets adjacent to the hood at a minimum height of 420 

mm from the hob (see figure). 

If the hob is installed beneath a wall cabinet, 

the latter must be situated at a minimum of 700 

mm above the hob.

•  The installation cavity should have the dimensions indicated in the figure.

  Fastening hooks are provided, allowing you to fasten the hob to tops that 

are between 20 and 40 mm thick. To ensure the hob is securely fastened 

to the top, we recommend you use all the hooks provided.

555 mm

55 mm

475 mm

•  Before fastening the cooktop in place, position the seal (supplied) along 

the perimeter of the countertop, as shown in the figure.

Hook fastening diagram

 

Hooking position for top 

H=20mm

  Hooking position for top 

H=30mm

 

 

Front

 

Hooking position for top 

H=40mm

 

Back

!

 Use the hooks contained in the “accessory pack”.

600mm min.

420mm min.

650mm min.