3. Rear Panel

15)   Voltage selector. Set the local voltage:  If any doubt, contact your dealer.  The unit is shipped with the selec-

tor set to 230VAC.

16)   Mains socket: The unit can be connected to the mains circuit by a standard IEC type power cord.  This socket 

contains a 6,3AT, slow blow fuse.  Use a screw driver to flip out the fuse compartment and to replace it by the 

same type.  When this fuse blows frequently, you should check the speaker load or bring the MA200R to a 

qualified service centre.  First check whether you didn’t use a quick-blow fuse!

17)   Zone 100V loudspeaker outputs: When you need to activate/deactivate separate loudspeaker zones, you 

should use these 100V outputs.  These connectors should only be used for 100V operation.  They are 

activated by the selectors at the front (see 4).  Don’t use these 100V outputs together with the 8 ohm, 50V 

or 70V terminals. The minimum impedance of all 100V loudspeaker lines together should be at least 50Ω 

(100Vx100V/50Ω = 200watt).

18)   Emergency power supply: You can power the amplifier directly from an emergency battery or power supply 

supplying 24V DC/20A.

19)   Loudspeaker outputs: For low impedance use com and 8Ω.  Keep impedance above 8Ω. 

For 50, 70 or 100V speaker lines use COM and 50, 70 or 100V terminals. 

For 100V operation, the total minimum impedance of the loudspeaker lines should be 50 Ω.  For 70V opera-

tion the minimum impedance should be 24,5 Ω and for 50V 12,5 Ω. 

Don’t mix the types of speaker connections.  Only one at the time should be used, unless you are able to 

calculate a combination which does not overload the amplifier (example: 100Ω at 100V for a loud zone in 

combination with 25Ω at 50V for a quiet zone).

20)   24V DC output: At this terminal (-/+) 24V DC will be available (max. 1A) from the moment a priority has been 

activated, to control priority relays of local volume attenuators or other devices.

21)   Power amp in / pre amp out: You can send the signal of the pre-amplifier to an external device such as an 

equalizer (APart PXQ2215) or limiter and feed the treated signal back into the amplifier via the power amp 

input.  From the “pre-amplifier out” you can also feed extra power amplifiers such as the Apart PA240P.  Don’t 

forget to feed the signal back into the “power amp in”.  When you don’t use this feature, the RCA bridge 

should be placed.

22)   Tuner output mono: Here you can recover a fixed signal of the internal tuner to feed other devices such as 

your telephone’s ‘music on hold’ system.

23)   Rec. out: When you need a copy of the total mix, you can connect this output to any recording device such 

as tape deck, MD recorder, VHS recorder, etc….You can also use this output to feed an extra amplifier.  This 

output level cannot be controlled separately.  When you connect your MA200R pre amp out or record out 

to a microphone input of another mixing amplifier, this input will have signal overload and the sound will be 

masked.  In this case you should use a line input, a DI-box or other signal levelling device.  Never connect 

this output to an amplifier loudspeaker output!