4.3.2. Safety valve

The safety valve (pressure safety device) must be inspected regularly to check that it is not clogged. Remove the limescale 

deposits if necessary. If the safety valve is equipped with a lever, regular valve correct operation check procedure can be 

performed with its help.

The drainage pipe of the safety valve may generate water droplets. It is not a defect; it is due to relief work function of the 

valve – pressure relief that occurs when water is heated in enclosed space of the inner tank.

4.3.3. RCD (Residual Current Device)

If the appliance comes with a residual current device (RCD) located on the power cord, and then after the tank of the water 

heater is filled with water and the system is checked for leaks, put in the moisture-proof electrical plug of the water heater 

and do the following:

- Press “RESET” on the RCD housing, LED will be lit, indicating electricity supply.

Then press “TEST”, power will be off, as well as LED. Press “RESET” again. If the power LED lit up, it means that the appliance is 

safe to use.

- If you press the “RESET” knob, but LED does not light up, contact the Technical Assistance Centre for advice by a competent 

person.

4.4. Please note:

4.4.1.

 When you first start the water heater, as well as on each start after disconnecting make sure that the water heater was 

filled with water, and only then make its connection to the mains.

4.4.2.

 When the power cord is damaged it must be replaced by a special cord. This cord can be purchased at the Technical 

Assistance Centre.

4.4.3.

 Hot water whose temperature exceeds 50°C at the user taps may immediately cause severe burns or even death. 

Children, the medically fragile and the elderly are more exposed to the risk of burns.

4.4.4. 

Water may drip from the water heater, so do not leave valuable items and equipment under the appliance.

4.4.5. 

If there is a chance that the temperature drops below 0°C in the room where the appliance is installed, drain the water 

from the water heater.

4.4.6.

 Outlets must be properly earthed.

4.4.7.

 While in operation, periodically clean the inner tank of the water heater. Particulate contaminants that are present in 

tap water may accumulate there.

4.4.8.

 When there is strong scaling in the heating elements or heavy settlings, drain water, remove the heating elements, and 

clean. When assembling them back follow these actions: tightening bolts should be done evenly, with no significant force 

applied, the fixing support should not be tilted. Electricity supply connection can be made only after filling the water heater.

4.4.9.

 When the water heater is not used for a long time, shut off the cold water supply valve and disconnect the water 

heater from the mains. If necessary, drain water.

4.4.10.

 When water pressure exceeds 5 bar, drops of water may appear in the drainage hole of the safety valve, or it may 

cause a leak.

• Rare drip at the drain hole of the safety valve indicates normal operation of the heater.

• Frequent drip at the drain hole of the safety valve means that the water pressure is higher than normal. In this case, the 

pressure reducer must be installed in the cold water supply pipe to reduce pressure at maximum distance from the heater.

• To remove appearing water drops, a discharge tube can be used, the end of which should be directed down to the drain, 

and it should not be blocked.

4.4.11.

 In case of water overheating, a thermal fuse conforming to European safety standards CEI-EN breaks the electric 

circuit at both leads to the heating element. 

4.4.12.

 Traces of the thermal insulation on the top of the outer shell are the technological features of the production process 

and are not defects. 

4.4.13.

 Before making call to the service center, make sure that the problem is not related to water or power outages.

Do not try to repair the appliance under by your own forces. Technical maintenance of the appliance must be carried 

out by a competent person. The data and specifications indicated are not binding and the Producer reserves the 

right to carry out any modifications that may be required without prior notice or replacement.

           

            

              

This product confirms to EU Directive 2002/96/EC-EU 2002/95/EC 

The symbol of the crossed waste paper basket on the appliance indicates that at the end of its working life the product 

should be disposed of separately from normal domestic household rubbish, it must be disposed of at a waste disposal centre 

with dedicated facilities for electric and electronic appliances or returned to the retailer when a new replacement product is 

purchased. 

The user is responsible for the disposal of the product at the end of its life at an appropriate waste disposal centre. The waste 

disposal centre (using special treatment and recycling processes effectively dismantles and disposes of the appliance) helps 

to protect the environment by recycling the material from which the product is made.

For further information about waste disposal systems visit your local waste disposal centre or the retailer from which the 

product was purchased.


Что удобнее для чтения книг?

Планшет
Электронная книга
Смартфон
Книга в бумажном переплёте
Не читаю книг

QR код manualbase.ru
©  2010- ManualBase.ru