31
Figure 3-16
Add VTO or fence station.
Step 4
Add main VTO.
In Figure 3-16
, enter main VTO name, IP address, “User Name” and “Password”.
1.
Switch “Enable Status” to
.
2.
Default device type is “Door Station”. VTO middle no. will be obtained
automatically. The format
is “1+building no.+ unit no. + VTO no.”. Building no.
has 2 digits, unit no. has 1 digit, and no. has 4 digits, so middle no. has 8 digits
in total.
“User Name” and “Password” shall be consistent with WEB login user name
and password of VTO. Otherwise, it will fail to connect.
“Enable Status” of main VTO is “ON” by default. After setting VTO info, please
turn it off and then reboot, in order to put it into effect.
Add fence station.
Press
to switch to sub VTO setting interface.
1.
Select device type to be “fence station”; enter sub VTO name (fence station name),
2.
VTO middle no. (fence station middle no.), “User Name” and “Password”.
Fence station middle no. consists of “1+00+0+fence station no.”; building no. is 00,
unit no. is 0 and VTO no. has 4 digits, so middle no. has 8 digits in total. For
example, 10006901.
Switch “Enable Status” to
.
3.
Click [OK] to save the settings.
Step 5