ENG

 Its  primary  function  is  the  power  supply  for  household  and  industrial  equipment,  which  is 

critical  to  the  input  current  waveform  (boiler  equipment,  automation  systems  with  equipment 

with program control (servers, databases, etc.) with medical equipment). 

 The  device  is  equipped  with  the  automatic  voltage  regulator  (AVR).  The  built-in  regulator 

enables  to  provide  correct  power  supply  at  overvoltage/undervoltage  of  the  mains  without 

going to the battery operation mode.

  The  automatic  start  function  provides  automatic  switching  on  when  there  is  power  supply. 

With input voltages 160 V or less, as well as 260 V or more the automatic start is not activated.

  The  three-stage  switch  of  charging  current  enables  the  user  to  connect  batteries  of  different 

capacities depending on the required time to provide the power backup. It is recommended for the 

battery with the capacity 20 – 50 А•h to use the position L (3-5 A) of the switch, with the capacity 50 – 

100 А•h to use the position M (7-9 A), with the capacity 100 – 200 А•h to use the position Н (13-15 A).

Recommendations regarding selection of batteries

 Select the capacity of a battery (batteries) depending on the connected load power and required 

time  of  power  standby,  see  the  table  1  below.  Based  on  the  selected  capacity,  choose  a  certain 

battery (batteries).

 Storage conditions of batteries must conform to the requirements of the battery producer.

 We recommend to use 

SVEN SV12170

SVEN SV12500

SVEN SV121000 

batteries.

Notes: 

 

When two or more batteries are used, they should be of one type and have the same capacity (if 

their capacities are different, the batteries will have different internal resistance and due to this the 

charge level will be different). 

 

Batteries  should  be  connected  in  parallel,  when  several  batteries  are  used  simultaneously. 

Additional  cables  (to  be  purchased  separately)  will  be  required  to  connect  extra  batteries.  When 

two  or  more  batteries  are  connected,  the  plus  terminal  of  one  battery  is  connected  to  the  plus 

terminal of the other battery, minus terminals of batteries are connected similarly. The connecting 

cables must have a sufficient cross-section and a minimum length.

Features

 Continuous action with prolonged back-up time

 Built-in automatic voltage regulator

 Pure Sine Wave

RT-500

RT-1000

RT-800

12V/50 А · h
12V/75 А · h

12V/100 А · h
12V/150 А · h

12V/200 А · h

3 h
5 h
7 h

12 h
15 h

1.5 h
2.3 h

3 h
5 h
7 h

0.7 h
1.5 h

2 h
3 h

4.5 h

0.5 h

1 h

1.5 h

2 h
3 h

0.4 h
0.8 h

1 h

1.5 h
2.5 h

0.4 h
0.8 h

1 h

1.5 h
2.5 h 

0.3 h
0.5 h
0.7 h

1 h
2 h

Load

100 W

Load

200 W

Load

300 W

Load

400 W

Load

480 W

Load

500 W

Load

600 W

Battery

capacity

Table 1. Selection of batteries

UPS for prolonged

power supply