1. The switch is off.

2. There is no power in the 

socket.

3. The bimetallic circuit- 

breaker 

i

 has activated.

The AVR is out of order.

Input voltage is very unstable.

• 

When the mains voltage exceeds the allowable rate (lower threshold is 140 V, upper threshold is 

260 V) the LED 

c

 illuminates, the AVR disconnects the load automatically and the LED 

d

 displays 

“L” or “H”.

Attention! It is recommended to switch off the AVR and every connected consumer-device 

when the power supply is dropped.

8. PAUSE FUNCTION

• 

The Pause mode feature is designed to protect equipment in case of frequent drops of the mains 

supply. This is particularly important for consumer appliances with electric motors or compressors. 

After power supply has been recovered, the AVR switches on within 6 or 180 seconds, depending 

on the "Пауза (Pause)" button (Вкл./Выкл. (ON/ OFF)) 

h

 position. 

9. PROTECTION FUNCTION AGAINST HIGH AND LOW INPUT VOLTAGE, OVERLOAD AND 

OVERHEAT 

• 

The stabilizer is equipped with an unique circuit overvoltage and undervoltage protection. In the 

case of mains voltage deviation over 260 V or below 140 V it turns off the load automatically. At the 

same  time  red  LED 

c

  illuminates,  and  the  display 

d

  shows  the  "H"  (for  activation  overvoltage 

protection) or symbol "L" (when triggered undervoltage protection). When the input voltage range 

returning to 140-260 V the stabilizer automatically resumes operation.

• 

In  case  of  overload  or  short-circuit  bimetallic circuit-breaker 

i

  will  triggered.  After  elimination 

overload cause or short circuits, press circuit-breaker button 

i

 (RESET position), and stabilizer will 

resume operation.

10. TROUBLESHOOTING

If  none  of  the  above  methods  can  solve  the  problem,  please  seek  professional  advice  at  your 

nearest service center. Never attempt to repair the product yourself. 

The AVR does not start.

The AVR is in operation mode, 

but there is no output voltage. 

The AVR often produces 

clicking sound.

1. Press the switch once again.

2. Make sure there is electric 

power supply.

3. Disconnect part of the load  

and switch on the AVR again.
Please address to an authorized 

service center.

The AVR is regulating output 

voltage.

Cause

Problem

Solution


Что удобнее для чтения книг?

Планшет
Электронная книга
Смартфон
Книга в бумажном переплёте
Не читаю книг

QR код manualbase.ru
©  2010- ManualBase.ru