- 18 -
EN
FILLING THE WATER TANK DURING USE
If the tank (M) should remain without water during use, the appliance will vibrate and its noise will become more intense; in
this case, switch off the appliance and unplug it from the mains power before filling the tank as described in the paragraph
“INSTRUCTIONS FOR USE”.
IMPORTANT: If the appliance is not promptly switched off, the pump might overheat and momentarily
cause the appliance to block. Fill the tank and wait a few moments for the appliance to start working again
normally.
We recommend checking the water level inside the appliance constantly and to fill the tank as described in the paragraph
“INSTRUCTIONS FOR USE”. In this case, it will not be necessary to switch off or unplug the appliance.
CLEANING AND MAINTENANCE
Emptying the water tank (M)
In case of a long period of disuse, take out the water tank and empty it, so as to prevent the formation of scale residues,
•
which might affect the normal operation of the appliance.
Emptying and cleaning the inside of the boiler tank
IMPORTANT: Clean the boiler tank at least once every month so as to remove any scale residues which
might affect the normal operation of the appliance.
IMPORTANT: Switch off the appliance, unplug it from the mains power and leave it to cool before cleaning
out the boiler tank, so as to avoid the risk of scalds.
Take out the water tank (M) and unscrew the cap in the rear part of the appliance (
•
15
).
Slowly add tap water to the boiler tank to prevent any spurts of steam; shake the appliance and turn it upside down to
•
empty it. Repeat the operation several times.
WARNING: Never add scale removers, vinegar or other perfumed substances to the tank, as these risk
damaging the appliance with immediate cancellation of the warranty.
Screw the cap on again and refit the water tank (M).
•
TROUBLESHOOTING...
PROBLEM
CHECK
POSSIBLE CAUSES
POSSIBLE REMEDY
No steam comes out of the
nozzle
Steam ready light (H)
off
Cold boiler tank
Wait for the steam ready
light to switch on (H)
Lack of water in the tank
(M) or badly inserted tank
(M)
Fill the tank (M) or position
it correctly
The nozzle is
dispensing little steam
Steam regulation dial (L) at
minimum
Lack of pressure
Adjust steam
dispensing
Cold boiler tank
Wait for the steam ready
light (H) to switch on