Power supply:
Max. 230-240V/AC, 50Hz
Power consumption,
Max. 1000W
Dimensions (L x W x H);
Weight;
3.5 kg
Fitting lamp
Maximum ambient temperature t
a
: 25°C
Maximum housing temperature t
S
: 140°C
Minimum distance:
1m
♦ Do not operate this device with opened housing cover!
Installing/Rigging
♦ This device can be installed on the ground or on the wall or ceiling.
When install it above head, please note the following information.
♦ The installation of the projector has to be built and constructed in a way that it can hold 10 times the weight
for 1 hour without any harming deformation.
♦ The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall
down if the main attachment fails.
♦ When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
♦ The projector should be installed outside areas where persons may walk by or be seated.
♦ The projector has to be installed out of the reach of people.
♦ If the projector shall be lowered from the ceiling or high joists, professional trussing systems have to be
used. The projector must never be fixed swinging freely in the room.
♦ Before rigging make sure that the installation area can hold a minimum point load of 10 times the
projector s weight.
♦
DANGER OF FIRE!
When installing the device, make sure there is no highly inflammable material
(decoration articles, etc.) within a distance of min. 1.0M.
♦ Mount the projector with the mounting-bracket to your trussing system using an appropriate clamp. The
hole in the mounting bracket has a diameter of 13 mm.
♦ For overhead use, always install a safety-rope that can hold at least 10 times the weight of the fixture.
♦ Adjust the desired inclination-angle via the mounting-bracket and fix the fixation screws.
Installing /Connection with the mains
♦
DANGER TO LIFE!
The electric connection must only be carried out by a qualified electrician!
♦ In order to connect the device to the mains, you have to install a power-plug.
♦ The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral N
Yellow/Green Earth
♦ The earth has to be connected!
♦ Connect the device to the mains with the power-plug.
♦ In general, lighting effects should not be connected to dimming-packs.
OPERATION:
♦ After you connected the spot to the mains, you can control the spot via your lighting
TECHNICAL SPECIFICATIONS
1.TRUSSING
1.TRUSSING
2.SAFETY-ROPE
2.SAFETY-ROPE
3.SCREW-ON
3.SCREW-ON
CARABINE
CARABINE
4.SAFETY-SCREW
4.SAFETY-SCREW
5.HOOK
5.HOOK
Controller
230-240 V GX9.5 650 W o 1000 W
370 x 250 x 370 mm