CIOKS AC Rider Link инструкция по эксплуатации онлайн - страница 2


Инструкция CIOKS AC Rider Link для устройства блок питания для педалей эффектов содержит страницы на английском языке.

Размер файла: 300.83 kB. Состоит из 2 стр.


Вы можете скачать pdf файл этой инструкции: Скачать PDF


12
Предыдущая
background image

Overview 
Front 

On the front of the enclosure you’ll find the 6 outlets of the power supply as RCA sockets 
where all DC outlets are centre positive. 
 
The red settings switch with two white knobs placed just to the right of the outlets should be 
used to set the output voltage of outlets 2 and 4. The very left knob is for setting of outlet 2 and 
the second on the most right for outlet 4. 
 

Knob no. * 

Function 

Knob down 

Knob up 

Outlet 2 

9V DC 

12V DC 

Outlet 4 

9V DC 

12V DC 

* counting from left, opposite order of the white digits on the red switch (if you can see them) 
 

Top 

CIOKS logo has a red LED placed in the middle of the letter ‘O’. When this LED is lit the 
power supply is connected to mains and operates. 
 
On top of the enclosure you see the output voltage and max. current rating of each outlet or 
section printed just above the outlet sockets. The top figure is the voltage and the DC or AC in 
the middle line tells you whether it’s a direct or alternate current outlet. Outlets with two 
possible voltage settings 9 or 12V have both values stated. The bottom figure states the 
maximum current capability of each outlet in mA. Isolated sections with two outlets sharing 
the same GND have one common figure for maximum total current which can be put out from 
both outlets in the section. 
 
The status of each isolated section or output is shown by a LED indicator also situated on top 
of the enclosure just above the voltage figure. The function of this advanced and unique 
monitoring feature is described in detail later on. 
 

Left side 

On the left side of the enclosure you’ll find the AC power input connector, which is a C6 type 
according to the IEC 60320 standard also used in many laptop adapters. On the same side as 
the AC mains input you’ll find the mains voltage selector switch and the fuse. 
 
Mains voltage selector switch should be used for setting the correct mains voltage 115 or 
230V. The Japanese version is made only for a 100V nominal mains voltage and has no mains 
voltage selector switch. 
 
The fuse is the only part which may be replaced by the user. In case it’s blown, replace with a 
5x20mm, T 315mA (slow blow/time lag) type. 
 

Right side 

On the right side you’ll find the AC mains courtesy outlet connector, which is a C13 type 
according to the IEC 60320 standard. The current drawn from this outlet should not exceed 2A. 
 
 

 

Bottom 

The four detachable rubber feet are situated on the bottom of the enclosure. On this same 
surface you’ll find 5 holes with metric M4 threads, which should be used for easy mounting of 
the power supply to a pedalboard. Do not use screws, which would go further than 5mm inside 
the unit. Have a look at the mounting guide on CIOKS web site. 

 
Getting started 

First make sure that the voltage value chosen on the voltage selector switch matches the mains 
voltage in your wall socket. Connect the mains power cord to the power supply and mains. 
Using the right Flex cable types connect your pedals to the outlets of power supply making 
sure that the voltage and current is correct for every pedal. 
 

Advanced LED Monitoring feature 

Each isolated outlet or section has its individual LED status indicator. The indicator is fully lit 
in normal operation of a particular outlet. Its light gets dim when you operate just on the edge 
of the current limit. If you overload or short circuit an outlet or section, the respective LED 
indicator turns off. 
 
The LED indicators of outlets 2 and 4 with selectable output voltages 9 or 12V, also show you 
the voltage set by the settings switch. In case a higher voltage than the default 9V setting is 
selected for a given outlet, its respective LED indicator will be lit with higher intensity than the 
other indicators. 
 
All indicators take into account the actual level of mains voltage when monitoring a possible 
overload. The current limits for each outlet or section of the power supply are specified at 
nominal level of the mains voltage. In Europe it’s 230V, 120V in e.g. United States and 100V 
in Japan. If the mains voltage is higher than nominal, you can draw more current from the 
power supply than stated in the specifications. This would never be a problem. A more 
common situation though, is when the mains voltage is lower than nominal. In such a case 
maximum current ratings for each outlet or section might be diminished. 
 
The advanced LED monitoring of each isolated section will alert you in case of an overload or 
short circuit. If such a situation happens you know where to look to solve the problem. 
A glance at the LED status indicators and you have proof of 100% clean power to your pedals. 
 

Included accessories 
Flex cables 

CIOKS offers a great selection of different Flex cable types for connecting your pedals to the 
power supply. Below you see a list of the included Flex cables with your unit: 
 

 

Type 1 – black with 5,5/2,1mm centre negative DC-plug 

x5 

 

Type 2 – red with 5,5/2,1mm centre positive DC-plug 

x1 

 

Type 4 – green with 5,5/2,5mm centre positive DC-plug 

x1 

 

Type 5 – black with 3,5mm tip positive jack-plug 

x1 

 

Type 7 – blue with 2 pin DIN plug 

x1 

12