ENG

18

Uninterruptible

Power Supply

1. PRECAUTIONS

Before operating this device, please carefully read the following safety instructions:

 Before switching on the Uninterruptible Power Supply (UPS) in the electric mains for the 

fi

rst time, 

it is necessary to charge the storage battery for at least 12 hours. For this purpose the UPS should 

be switched on without load. 

 If the storage battery has fully run down or the UPS has not been operated for three months, it is 

also necessary to charge the storage battery for at least 12 hours. Otherwise, its durability will be 

considerably reduced.

 We pay your attention that batteries composing UPS are consumables and are not subject to 

warranty replacement.

 The UPS is designed solely for operation with PCs equipped with switching power supply units*. 

It is strongly forbidden to connect inductive or capacitive load, as well as fully resistive load. Such 

loads include any devices with transformer power unit, electric engines, 

fl

uorescent lamps, laser 

printers, any heating appliances, etc.

 During operation, the case of the device can be heated up to 50°C, which is absolutely normal.

 It is strongly forbidden to open case of the device, as there is high voltage inside. If some prob- 

lems occur, please address an authorized service centre. For the list of authorized service centres 

please go to 

www.sven.

fi

.

 Do not let liquid and foreign objects get inside the device, it can cause short circuit or electric 

shock.

 In case there are signs of improper operation of the device (sparkling, unusual smells, etc.), it is 

necessary to turn o

 the device immediately and disconnect it from the mains, and address your 

nearest authorized service centre. 

 It is forbidden to connect the UPS to equipment with power consumption higher than 

its maximum output power. It can cause overload and breakdown of the device.

It is strongly forbidden to operate the device in following conditions:

 in dusty environment or environment containing highly in

fl

ammable gas;

 at temperature higher than 40°C or lower than 0°C;

 at relative humidity level higher than 90%;

 in direct sunlight or next to heating elements;

 in vibration places;

 outdoors.

 In case of 

fi

re use only powder 

fi

re extinguisher, as using water can cause electric shock.

 Try to install the UPS in proximity to power supply, in such way it will be easier to unplug the device 

if necessary.

*The device operation is not guaranteed when connecting UPS with APFC (active power factor 

correction). 