14
T: Timer key:
pressing this key when the extractor fan is switched on will activate the shut-
down function after 15 minutes. Turn off the extractor fan and the light. The active function is
signalled with the red LED light flashing. The timer function, if activated, will be deactivated
when pressing the timer key again. The function is also deactivated when pressing the 0/1
key if the extractor fan has switched off. The key will light up permanently to signal, when the
extractor fan is switched off, to clean the aluminium filters after 30 hours of operation. Applying
prolonged pressure will reset the signal.
DEC:
Deceive the automatic function is activated it will be deactivated. If the extractor fan is
in operation, it will reduce the speed and if the ioniser is activated it will reduce the power of
the ioniser.
0/1:
If the automatic function is activated, it will be deactivated. If the extractor fan is switched
off, it will be activated to the first speed. If the extractor fan is in operation, it will be switched
off. With the extractor fan and the light switched off, applying prolonged pressure it will enable
the activation/deactivation of the ioniser. The ioniser has been activated if the Auto key lights
up during the prolonged pressure.
INC:
If the automatic function is active it deactivates it. If the extractor fan is in operation,
pressing the key will increase the speed up to intensive and, if the ioniser is activate, it will
increase ionising power. The intensive has a 14 minute duration, after which time the extractor
fan will return to the 3rd speed. The intensive function is signalled by the flashing INC LED.
Note: 3 speeds are active in the SPRING model hood featuring 2 motors and the maximum
speed is not timed.
Auto:
With extractor fan switched off the automatic mode will be activated/deactivated; if
activated the auto LED will be lit. In this mode, if the air quality is good, (completely green leaf)
the extractor fan and the ioniser are switched off. If the quality of the air has deteriorated, the
leaf is partially or completely yellow, the extractor fan is activated at the first speed and the
DEC LED lights up until the leaf turns completely green.
L:
The brief pressure activates/deactivates the light. With the extractor fan and light switched
off, applying prolonged pressure enables the memorisation of the RF remote control. The key
flashes for a few seconds or until the remote control key is recognised.
When the extractor fan is enabled in normal functioning mode the ioniser (with increasing
power according to the level of air pollution) is also activated.
FILTERS
REMOVING AND REPLACING’S INSTRUCTIONS
F
1. METAL FILTERS
To remove the metal filters, remove the lower panel fastened with one of the magnets of
the range hood. This way, the filters can be removed by using the appropriate handle.
2. COMBINED AND REGENERABLE FILTERS (qualified personnel only)
The CARBON-ZEO filters can be regenerated according to the procedures described in
paragraph H regarding maintenance. These filters are placed in the upper side of the
range hood. Follow the instructions below to remove them (see fig. F2):
- Disconnect the appliance from the mains.
- Loosen the 2 screws (V1) (4 screws for SPRING double motor range hood).
- Carefully remove the combined filter-holder (SF) (2 filter-holders for the SPRING double
motor range hood)
- Remove the filter (F) from the combined filter-holder (SF).
To order new charcoal filters, contact your distributor/dealer.
ONLY FOR ITALY:
Download the filter order module from the website: www.falmec.com.