THERMEX ERD 50 V инструкция по эксплуатации онлайн - страница 13


Инструкция THERMEX ERD 50 V для устройства водонагреватель накопительный содержит страницы на русском языке.

Размер файла: 2.75 MB. Состоит из 52 стр.


Вы можете скачать pdf файл этой инструкции: Скачать PDF


Предыдущая
Следующая
background image

0,05 / 0,6

2

3

0, 50

1,5

1/2

IPX4

+

3

...+

40

+18…+74

 ±5

Cold water line pressure, MPa min/max

Supply – single-phased, voltage, V, frequency, Hz

 

 

Electric Heating Bundles capacity, kW

 

Diameter of thread of nipples of cold and hot water connections

Water heater protection class

Operation at environmental temperature, °

С

Water heating control range °

С

С 

Storage mode temperature maintenance accuracy, °

Please, read the present manual before starting to use the water heater and pay attention to 
the “ATTENTION!” items

The present manual is made for a water heater's model ER of from 50 to 150 liters volume and model 

Е

S of 

from 30 to 80 liters volume. A full name of the model of the heater is indicated on an identification plate 
located in a frame body of the heater.

Supply set

Water heater with PTD (optional)

 

1 un.  

Safety valve of GP type 

 

1 un.  

Operation manual   

 

1 un.  

Package   

 

 

1 un.  

Purpose

An electric water heater (hereinafter referred to the EWH) is designed to provide with hot water household 
and industrial users equipped with a cold water supply line with the required parameters.

The heater shall be used in closed heated rooms and not designed for operation in continuously flowing 
mode.

Main Technical Specifications

The manufacturer reserves the right to introduce changes into water heater design and characteristics 
without prior notice.

Operation

Internal reservoir has a special surface made of bioglass-porcelain material that safely protects an internal 
surface from electrochemical corrosion.

On  a  removable  flange  are  assembled:  an  electric  heating  bundle  (EHB)  (

7

),  a  thermostat  (

8

)  and  a 

magnesium  anode  (

9

).  The  EHB  is  made  for  water  heating  and  the  thermostat  provides  a  heating 

temperature regulation up to +74°

С

 (±5°

С

). The magnesium anode is designed to counteract an effect of 

electrochemical corrosion to the internal reservoir.

The regulation is made using a handle of a thermostat controller (

10

) located onto a protective cover of the 

heater. The thermostat also has a thermoswitch – a protection heat device that cuts off the EHB from the 
power network if a water temperature exceeds +93°

С

 (±5°

С

).

 In the course of operation the heater case 

body can be heated. It is not a breakage when the heater's thermal protection is activated. To make the 

EN

heater back to operation mode is made by pushing a stock of a thermoresponsive switch located under the 
heater's cover (

Fig. 3

).

Onto a protective cover of the device there are two control lamps (

11

): a control lamp of a red color is lighted 

up constantly if the heater is connected to a power supply network; a control lamp of an yellow color shows 
a  heater's  operation  mode;  it  is  lighted  on  when  water  is  heated  and  switched  off  when  the  set-up 
temperature is reached. In an electrical cable of the heater (optional) there is a protection tripping device 
(PTD) provided the heater's cut off from the power network in case of leakage current occurrence on 
grounded elements of the device.

Installation and connection

All assembly, plumbing and electrical installation works shall be performed by skilled staff.

Location and installation

Installation of an electric water heater (EWH) shall be made in accordance with the marking specified onto 
a body frame and the following table:

EWH model

Volume

,

 l

Design

ER V

50 -150 

vertical

 

ER H

50 -150 

horizontal

 

ES V

30 - 80 

ES H

30 - 80 

vertical

 

horizontal

 

It is recommended to install the electric water heater as the closest as possible to a place of use of hot 
water in order to reduce a waste of heat in pipes. The heater shall be hung on anchors hooks (not included 
in a supply set) fixed to a wall. For mounting it is recommended to use anchors (hooks, studs or bolts) with 
diameter of not less than 8 mm. Depending on a model you will need 2 or 4 anchors. A type of these 
anchoring elements shall be selected in accordance with a wall material.

Mounting of hooks in a wall shall prevent a self-movement of the heater's brackets. When selecting a place 
of installation total weight of the EWH filled with water shall be taken into account. A wall and a floor that 
have poor loading capacity shall be strengthened. To maintain the heater a distance from a protection 
cover to the closest surface towards an axis of a removable flange should be not less than 0.5 meter.

To avoid damage of a consumer's belongings and (or) a property of third parties in case of breakage of a 
hot-water  supply  system  the  assembling  of  the  heater  shall  be  made  in  rooms  that  have  a  floor 
waterproofing and canalization draining. It is prohibited to place under the heater the things subject to 
effect of water. When installing the electric water heater in unprotected facilities it is required to install 
under it a protective tray (not included in a supply set) with canalization draining.

Shall the heater be installed in places that are difficult to approach to make maintenance operations and 
warranty services (ceiling shelves, niches, ceiling spaces) assembly and dismantling works are made by a 
consumer himself or at his expense.

Connection to water supply

It  is  necessary  to  pump  cold  water  in  EWH  using  prime  water  filter  with  the  degree  of 
purification not less than 200 microns.

Install the safety valve (

17

) on cold water input (

21

) - the pipe nipple with the blue ring, on 3.5 - 4 turns, 

having provided tightness of connection with any sealing material (flax, PTFE tape, etc.).

The safety valve carries out functions of the non-return stop valve, interfering water backflow from water 
heater to water supply system in the cases when the pressure decreases in the last one, and in the cases 
when the pressure increases in a tank at strong water heating, and also carries out the function of the 
protective valve, dumping excessive pressure in a tank at strong water heating. When water heater is 