Eng

SMART 700 VA/1000 VA/1400 VA

1. INTRODUCTION

Thank you for purchasing our Smart Series UPS products. Please read the USER’S MANUAL before installing your Smart UPS. It pro-
vides the information that should be followed during the installation, safety instruction, customer support, and troubleshooting. If you expe-
rience a problem with the Smart UPS, please refer to the Troubleshooting Table in this manual to correct the problem. Or, collect enough
information so that our Technical Support Department can assist you rapidly.
Our Smart UPS is an extremely reliable sine wave uninterruptible power system designed to keep computers and peripheral devices such
as monitors, storage subsystems, modems, tape drives, etc. performing from utility line failures which could result in damage of data. In
the event of utility failure, the Smart UPS supplies power to your equipment derived from a battery within the UPS and provides visual
and audible indicators which alert you to utility line failures. Therefore, the user has ample time to save file and close operations.
Whenever the Smart UPS is plugged in, the Smart UPS maintains the battery in a charged condition and serves to protect your equip-
ments from surges and noise brought from utility.

The main features include:

Pure sine wave output.

Automatic Voltage Regulation (AVR).

Advanced equipment & data protection from blackouts, brownouts, sags, AC line noise and surges.

Adjustable input power range settings to meet your power source requirement.

Full analytical high performance micro processor control with true RMS synchronous calculation

Intelligent battery management for battery status, battery power saving & battery replacement control.  

DC direct start up capability, complete diagnostic indication and control.

Standard RS-232 communication interface.

Telephone RJ11 & Network RJ45 surge protection.

Expansion slot is for optional SNMP CARD for network management / monitor.

2. INSTALLATION AND SAFETY INSTRUCTIONS 

Receiving Inspection

Once you have received the UPS, you should remove and inspect the unit for shipping damage. If damage is found, immediately notify
the carrier and your dealer. The carton and foam materials in which the UPS was shipped to you were designed with great care to pro-
vide protection from transportation related damage. You should keep both the shipping carton and the packing foam in case the UPS
must be returned to the factory for service (damages sustained in transit when shipped from the user are not covered under warranty).

Important Safety Instructions

All safety and operating instructions should be read before operating your UPS. These UPS units are intended for use in a temperature-
controlled, indoor area free of conductive contaminants. Select a location which will provide good air circulation for UPS at all times.

FOR THE FIRST TIME USE, YOUR UNIT SHOULD BE PLUGGED IN (THE POWER I/O SWITCH DOES NOT HAVE TO BE ON) FOR
AT LEAST 6 HOURS TO FULLY CHARGE THE BATTERY.

CAUTION

——- A battery can present a risk of electrical shock, burn from high short-circuit current. Observe proper precautions.

CAUTION

——- When replacing batteries use the same number and the following type batteries given in the Specifications section of

this manual.

CAUTION

——- Proper disposal of batteries is required. Refer to your local codes for disposal requirements.

Installation
1. Conditions

Do not operate the UPS in an environment where the ambient temperature is outside the limits given in the specifications of this manual.

2. Connection to the utility 

There is a 2-dip switches located on the rear panel and set to the default position applicable to your power source voltage requirement.
Check with your dealer for the right setting before you proceed the installation procedure.
The 240/220/210Vac version UPS is furnished with one output power cords for connection to computer equipment having «IEC 320» male
appliance couplers at their input. In most cases this will not be a problem as the input cord which currently powers your computer equip-
ment may be swapped with one of the supplied output cords. Hence, the swapped output line cord can be used instead as the input line
cord for the UPS.

3. Initial battery charging

The UPS is shipped from the factory with its internal battery in a fully charged state. However, the battery may be losing some charge
during shipping and storage. The battery should be recharged before conducting the following Test for proper operation and to ensure
that UPS will provide expected run time. The battery is automatically charged by the UPS whenever the UPS is plugged in (the power
I/O switch does not have to be on). You can be sure that the battery is fully recharged if the UPS is left plugged in for at least 8 hours.

4. Connecting your equipment to the UPS

13


Что удобнее для чтения книг?

Планшет
Электронная книга
Смартфон
Книга в бумажном переплёте
Не читаю книг

QR код manualbase.ru
©  2010- ManualBase.ru