SILENT-100 CRZ DESIGN 

This model is provided with an adjustable 
over-run timer. The timer allows the fan 
to continue to operate for the selected 
period after the switch has been turned 
off (fi g.6).
Model provided with a 4 positions adjus-
table electronic timer: Fig.5 shows how 
to connect the fan with timer utilising the 
same switch as for the lighting circuit.
To set the timer, turn the potentiometer on 
the printed circuit board as (fi g. 7).

-To reduce the “run on” time, turn 

anticlockwise (min. 1 minute)

-To increase the “run on” time, turn 

clockwise (max: 30 minutes).

SILENT-100 CHZ DESIGN

Models provided with an electronic 
humidistat which can be adjusted from 
60% to 90 % RH (relative humidity) and 
with a timer, adjustable between 2 and 
20 minutes. 

Operation
Case 1: 

Automatic operation (fi g.9)

In automatic operation, the humidistat 
causes the extractor to operate auto-
matically when the humidity level in the 
room is higher than the set level. The 
extractor will stop automatically when 
the humidity drops below the selected 
level and after the selected period set 
on the timer.

Case 2:

 Automatic operation as in case 1 

with the facility to override the hygrostat 
by means of the light switch (fi g.8), when 
the humidity level in the room is lower 
than the selected level.  In this case, the 
extractor continues to operate for the 
selected period set on the timer after the 
switch light has been switched off.

ATENTION: When the humidity rate is 
above the selected value, the automa-
tic option takes precedence over the 

manual and the unit cannot then be 
switched off using a switch.

The desired humidity level is selected 
by means of a potentiometer “% Hr” 
positioned on the printed circuit board 
(fi g.10) and accessible once the grille (1) 
has been removed.

- To increase the humidity setting turn 

anticlockwise (min.60 %)

- To reduce the humidity setting turn 

clockwise (max. 90 %)

To set the timer, turn the potentiometer 
“t min.” on the printed circuit board 
(fi g.10):

- To reduce the “run on” time, turn 

anticlockwise (min. 2 minutes)

- To increase the “run on” time, turn 

clockwise (max: 20 minutes).

Maintenance

The extractor fan only requires periodical 
cleaning using a cloth lightly impregnated 
with a soft detergent.

After Sales Service 

We recommend you not to try to dis-
mantle or remove any other parts than 
those mentioned as any tampering would 
automatically cancel the S&P guarantee. 
If you detect any fault, contact your S&P 
dealer.

S&P reserves the right to alter specifi ca-
tions without notice