Working modes:
This unit can work under following modes:
1. Inverter Mode
Please connect red cable to “+” of inverter and screw tightly, connect black
cable to “-” of inverter and screw tightly; then connect clip of red cable
to “+” of battery, clip of black cable to “-” of battery, last turn on to use
(reverse connection is forbidden, otherwise will badly damage the
device).
- Screw in terminal post, but not too tightly.
- Connect the black clip to the negative pole of battery; connect the red
clip to the positive pole. If it is too loosen, will result no current, wire heat,
and damage the power inverter or cause the fire.
- Turn on the power inverter; connect this device with the applicant to be
used.
- If you don’t use the power inverter, please disconnect the wires.
2. Charge mode
Please connect red cable to “+” of inverter and screw tightly, connect black
cable to “-” of inverter and screw tightly; then connect clip of red cable to
“+” of battery, clip of black cable to “-” of battery. Then insert charging plug
into Utility Power socket, which will charge the battery. It will switch to
floating status automatically when fully charged. (Yellow indicator light
should be ON when charging, OFF when fully charged)
3. UPS Mode
Please connect red cable to “+” of inverter and screw tightly, connect black
cable to “-” of inverter and screw tightly; then connect clip of red cable to
“+” of battery, clip of black cable to “-” of battery. Then insert charging plug
into Utility Power socket, finally turn on the inverter’s switch. When input
with Utility Power, inverter circuit stops automatically, AC output socket
voltage will be Utility Power voltage, charging the battery automatically
at the same time, It will switch to floating status automatically when fully
charged; When Utility Power interrupted, it will switch to battery power
supplying status within 4 seconds, convert to AC electricity through this
device
User manual