ENGLISH

SILENT-100 DESIGN Axial Extractor 
Fans

The SILENT-100 extractor fan range is 
manufactured to the high standards of 
production and quality as laid down by the 
international Quality Standard ISO 9001. 
All components have been checked and 
every one of the fi nal products will have 
been individually tested at the end of the 
manufacturing process.
On receipt of the product we recommend 
that you to check the following:

1- That it is the correct model.
2- That the details on the rating label are 
those you require: voltage, frequency...
The installation must be carried out in 
accordance with the electrical standards 
in force in your country.
This appliance is not intended for use by 
young children or infi rm persons unless 
they have been adequately supervised by 
a responsible person to ensure that they 
can use the appliance safely. Young chil-
dren should be supervised to ensure that 
they do not play with the appliance

Installation
IMPORTANT: 

Before installing and wiring 

the unit, ensure that the main supply is 
disconnected.

Fig. 1:
1 : Protection grille 

 

2 : Connection terminals
3 : Outlet with backdraught shutter
4 : Cable entry

The SILENT-100 is suitable for wall or 
ceiling mounting and can either discharge 
directly to the outside or via an individual 
ducting system (see Fig. 2).
The unit can be mounted on the wall or 
ceiling using the 4 rubber blocks and the 
screws provided.

Make a hole in the wall or ceiling of 
105 mm dia.
If the unit is to be installed with indivi-
dual ducting, use a standard 100 mm 
dia. duct.
Ensure that there are no obstructions 
to the airfl ow and that the impeller 
turns freely.
Fix the extractor to the wall in such a way 
that it is not distorted in order to avoid 
noise generation or problems with the 
rotation of the impeller. Make sure that 
the backdraught shutter opens freely 
and has not being damaged in transit. 
Introduce the mains cable through the 
cable entry (4) and fi x it to the wall. 
Connect the electrical wiring as set out 
below and then mount the protection 
grille (1).

Electrical connection

The SILENT-100 is an extractor designed 
for a single phase supply, with voltage 
and frequency as indicated on the 
rating plate of the unit. The units are 
manufactured with double electrical 
insulation
(Class II) and therefore they do not need 
an earth connection.
The electrical installation must include 
a double pole switch with a contact 
clearance of at least 3 mm.
The electrical cable must enter the SI-
LENT-100 through the cable entry (4).
Once the cable has been introduced pro-
ceed using the electrical wiring diagram 
applicable to the selected model.

SILENT-100  CZ DESIGN

For these models use the following 
diagrams:

Fig.3: Switching the extractor through 
the light switch.
Fig.4: To switch the fan through an 
independent switch.