OMRON R5 Prestige инструкция по эксплуатации онлайн


Инструкция OMRON R5 Prestige для устройства тонометр содержит страницы на русском языке.

Размер файла: 2.63 MB. Состоит из 2 стр.


Вы можете скачать pdf файл этой инструкции: Скачать PDF


12
Следующая
background image

I

H

C

D

E

F

G

B

1

2

Blinking

J

K

L

M

N

O

P

Q

R

S

X

Y

V

U

T

W

A

Important Safety Information

Introduction

1.   Overview

Main unit: 

Display: 

2.1   Installing/Replacing the Batteries

2.   Preparation

1.

2.

3.

1.

1.

2.

2.

2.2   Setting the Date and Time

2.3   Setting the Advanced Positioning Sensor

3.   Using the Unit

1.

3.1   Applying the Wrist Cuff

3.3   Taking a Reading

3.2   How to Sit Correctly

Setting the Wrist for Measurement

Setting the Buzzer

Resetting to the Default Setting

Relax your wrist and hand.

3.4   Using the Memory Function

Do not bend 
your wrist back.

Do not clench 
your fist.

Do not bend 
your wrist forward.

Digital Automatic 

Wrist Blood Pressure 

Monitor

Model R5 Prestige

Instruction Manual

Thank you for purchasing the OMRON R5 Prestige Digital Automatic Wrist 
Blood Pressure Monitor.
The OMRON R5 Prestige is a compact and easy to use blood pressure 
monitor, operating on the oscillometric principle. This well designed wrist 
monitor comes with memory for two users and a easy to read Blood pressure 
level indicator allowing you to easily see if your readings are with in the 
Guidelines set by the World Health Organization. It measures your blood 
pressure and pulse rate simply and quickly. For comfortable controlled inflation 
without the need of pressure pre-setting or re-inflation the devices uses its 
advanced “IntelliSense” technology.
Intended Use
This product is designed to measure the blood pressure and pulse rate of 
people within the range of the designated wrist cuff, following the instructions in 
this instruction manual.
It is mainly designed for general household use. Please read the Important 
Safety Information in this instruction manual before using the unit.

Please read this instruction manual thoroughly before using the unit.
Please keep for future reference.
For specific information about your own blood pressure, CONSULT YOUR 
DOCTOR.

Consult your doctor prior to using in pregnancy or if diagnosed with arrhythmia 
or arteriosclerosis.
Please read this section carefully before using the unit.

Warning: 

• Indicates a potentially hazardous situation which, if not avoided, could result 

in death or serious injury.

(General Usage)

• Always consult your doctor. Self-diagnosis of measurement results and 

self-treatment are dangerous.

• People with severe blood flow problems, or blood disorders, should consult a 

doctor before using the unit, as cuff inflation can cause internal bleeding.

(Battery Usage)

• If battery fluid should get in your eyes, immediately rinse with plenty of clean 

water. Consult a doctor immediately.

Caution:

 

• Indicates a potentially hazardous situation which, if not avoided, may result in 

minor or moderate injury to the user or patient or damage to the equipment or 
other property.

(General Usage)

• Do not leave the unit unattended with infants or persons who cannot express 

their consent.

• Do not use the unit for any purpose other than measuring blood pressure.
• Do not disassemble the unit or wrist cuff.
• Do not inflate the wrist cuff over 299 mmHg.
• Do not use a mobile phone or other devices that emit electromagnetic fields, 

near the unit. This may result in incorrect operation of the unit.

• Do not operate unit in a moving vehicle (car, airplane).

(Battery Usage)

• If battery fluid should get on your skin or clothing, immediately rinse with 

plenty of clean water.

• Use only two “AAA” alkaline (LR03) batteries with this unit. Do not use other 

types of batteries.

• Do not insert the batteries with their polarities incorrectly aligned.
• Replace old batteries with new ones immediately. Replace both batteries at 

the same time.

• Remove the batteries if the unit will not be used for three months or more.
• Do not use new and used batteries together.

General Precautions

• Do not apply strong shocks and vibrations to or drop the unit.
• Do not take measurements after bathing, drinking alcohol, smoking, 

exercising or eating.

• Do not inflate the wrist cuff when it is not wrapped around your wrist.
• Do not wash the wrist cuff or immerse it in water.
• Read and follow the “Important information regarding Electro Magnetic 

Compatibility (EMC)” in the Technical Data Section.

• Read and follow the “Correct Disposal of This Product” in the Technical Data 

Section when disposing of the device and any used accessories or optional parts.

A. Display
B. Battery compartment cover
C. Wrist cuff
D. MEM (Memory) button
E. O/I START (    ) button

F.  User ID selection switch
G. SET  button
H. Date/Time setting (    ) button
I.  Date/Time setting (    ) button

J. Deflation symbol
K. Systolic blood pressure
L. Positioning indicator
M. Diastolic blood pressure
N. Memory symbol 
O. Average value symbol 
P.  Irregular heartbeat symbol 
Q. Movement error symbol 

R. User ID symbol (A or B)
S. Wrist (left/right) symbol
T.  Battery low symbol
U. Pulse display
V. Heartbeat symbol
W. Date/Time  display
X. Buzzer symbol
Y.  Blood pressure level indicator

Remove the battery cover.
1) Push the hook on the bottom of 

the battery cover.

2) Pull the cover off the main unit.

Insert two 1.5V “AAA” alkaline (LR03) 
batteries as indicated in the battery 
compartment and set the date and 
time (refer to section 2.2).

Replace the battery cover.

The Advanced Positioning Sensor will assure you the unit is in the correct 
position level with the user’s heart before the monitor starts to take the 
measurement.

Selecting the User ID

Before setting the Advanced Positioning Sensor, select your User ID.

Setting the Positioning Indicator

Notes:
• If the battery low symbol (     ) appears on the display, turn the unit off 

then replace both batteries at the same time.

• The measurement values continue to be stored in memory even after 

the batteries are replaced.

Disposal of used batteries should be carried out in accordance with the 
national regulations for the disposal of batteries.

Set the monitor to the correct date and time before 
taking a measurement for the first time.

Press the     button.

Do not apply over clothing.

Place the wrist cuff over your wrist.

Wrap the wrist cuff around your wrist.

Your thumb should face upward.

Make sure that the wrist cuff does not cover 
the protruding part of the wrist bone (ulna) on 
the outside of the wrist.

Notes:
• You can take a measurement on either your 

left or right wrist. Refer to 2.3 about how to 
modify the settings.

• The blood pressure can differ between the right 

arm and the left arm, and therefore also the 
measured blood pressure values can be 
different. OMRON recommends to always use 
the same arm for measurement. If the values 
between the two arms differ substantially, 
please check with your physician which arm to 
use for your measurement.

• Wrap the wrist cuff securely around the wrist 

for taking accurate measurements.

Press the O/I START button to turn the monitor off.

Notes:
• To reset the date and time, hold down the      button while the power 

is off.

• If the batteries have been removed for 30 seconds or more, the date 

and time setting will need to be reset.   

1) Push the     button to change.

• Hold down to advance the 

digit rapidly.

2) Push the     button to confirm.

Next setting appears.

3.

Push the      button to choose which mode of Positoning 
indicator you wish to have.

While setting the Positioning indicator the blue light flashes.

 

on1

: After the Positioning indicator lights in blue for more than 2 

seconds, or in orange for more than 5 seconds, measurement 
starts automatically, even though the monitor is not in proper 
position.

on2

: The Positioning indicator lights in blue for more than 2 seconds, 

measurement starts automatically. Measurement will not start if it 
lights in orange.

oFF

: Measurement starts without the Positioning indicator.

Push the      button to confirm your choice and move 
onto the next step.

Note: If you choose “oFF” for the Positioning indicator, the monitor will 

skip the process of choosing which wrist.

Year

Month

Day

Hour

Minute

To take a measurement, you need to be relaxed and comfortably seated, under 
comfortable room temperature. No eating, smoking or exercising 30 minutes 
before taking a measurement.

• Sit on a chair with your feet flat on the floor.

To Delete All the Values Stored in Memory

The values stored in the memory are deleted by user ID.
You cannot partially delete values stored in the memory. All values for the 
user you select will be deleted.

When the memory symbol (     ) appears, first press the MEM button. Then 
while holding it down, press the O/I START button simultaneously for about 
2-3 seconds.

Note:  You cannot partially delete the stored readings.

Sit upright with your 
back straight.

The cuff should be at the 
same level as your heart.

First

Second

Do not use your other hand 
to support the wrist cuff. 
This can result in inaccurate 
measurement results.

Notes:
• This section is the example for the measurement with the default 

setting. To change the setting refer to section 2.3.

• To cancel a measurement, press the O/I START button at any time 

during measurement.

• Remain still while taking a measurement.

Select your User ID.

Always use the same user ID when taking a measurement.
The unit stores the measurement values in the selected user ID 
memory.

Notes:
• If “GUEST” is selected, A or B will not be displayed.
• If “GUEST” is selected, the measurement results are not stored in the 

memory.

2.

Press the O/I START button.

While your position is improper, the Positioning indicator lights in 
orange, when you are in proper position the buzzer beeps “beep beep 
beep” and the Positioning indicator turns to blue.

The monitor automatically stores the result up to 90 sets each for both 
user A and B. It can also calculate an average reading based on the 
measurements from the last three readings taken within 10 minutes. If 
there are only two readings in memory for that period, the average will 
be based on two readings. If there is one reading in memory for that 
period, the average will be based on one reading.

Note:  If the memory is full, the monitor will delete the oldest readings.

Important:

• Recent research suggests that the following 

values can be used as a guide to high blood 
pressure for measurements taken at home.

Systolic Blood Pressure    Above 135 mmHg

Diastolic Blood Pressure  Above 85 mmHg

 

This criteria is for home blood pressure 
measurement.

• Your blood pressure monitor includes an irregular 

heartbeat feature. Irregular heartbeats can influence 
the results of the measurement. The irregular 
heartbeat algorithm automatically determines if the 
measurement is usable or needs to be repeated. If 
the measurement results are affected by irregular 
heartbeats but the result is valid, the result is shown 
together with the irregular heartbeat symbol (     ). If 
the irregular heartbeats cause the measurement to 
be invalid, no result is shown. If the irregular 
heartbeat symbol (     ) is shown after you have taken a measurement, 
repeat the measurement. If the irregular heartbeat symbol (     ) is 
shown frequently, please make your doctor aware of it.

3.
4.

Undo the wrist cuff and remove the unit.

Press the O/I START button to turn the monitor off.

The monitor automatically stores the measurement in its memory.
It will automatically turn off after 2 minutes.

Average Value

Previous Reading

Alternating 
date/time display

View the Average 
Value

View Previous Reading

View Readings Stored 
in Memory

•  Hold down to view 

readings rapidly.

4.3   Maintenance

To protect your unit from damage, please avoid the following:

• Subjecting your unit to extreme temperatures, humidity, 

or direct sunlight.

• Washing the cuff or exposing the cuff or unit to water. 
• Disassembling the unit.
• Subjecting the unit to strong shocks or vibrations. 

Dropping the Unit.

• Cleaning the unit with volatile liquids.

• 

The unit should be cleaned with a soft, dry cloth.

• Use a soft, moistened cloth and soap to clean the cuff.
• Keep the unit in its storage case when not in use.
Do not store the unit in the following situations:
• If the unit is wet.
• Locations exposed to extreme temperatures, humidity, 

direct sunlight, dust or corrosive vapours.

• Locations exposed to vibrations, shocks or where it will 

be at risk of falling.

Calibration and Service

• The accuracy of this blood pressure monitor has been 

carefully tested and is designed for a long service life.

• It is generally recommended to have the unit inspected 

every two years to ensure correct functioning and 
accuracy. Please consult your authorised OMRON 
dealer or the OMRON Customer Service at the address 
given on the packaging or attached literature.

5.   Technical Data

Note:  Subject to technical modification without prior notice.

Product Description
Model
Display
Measurement Method
Measurement Range

Accuracy

Inflation
Deflation
Memory

Power Source
Battery Life

Applied Part

Protection Against 
Electric Shock
Operating temperature/ 
Humidity
Storage temperature/ 
Humidity/ Air pressure
Console Weight
Outer Dimensions

Measurable 
circumference of wrist
Cuff Material
Package Content

Digital Automatic Wrist Blood Pressure Monitor
OMRON R5 Prestige (HEM-6052-RU)
LCD Digital Display
Oscillometric method
Pressure: 0 mmHg to 299 mmHg
Pulse: 40 to 180 beats/min.
Pressure: ±3 mmHg
Pulse: ±5% of reading
Automatic inflation by pump
Automatic rapid deflation
90 Measurements with date and time for each user 
(A and B)
2 “AAA” alkaline (LR03) batteries 1.5V
Approx. 300 measurements with new alkaline 
batteries at a room temperature of 23˚C

Internally powered ME equipment

+10˚C to +40˚C / Maximum: 30 to 85% RH

-20˚C to +60˚C / Maximum: 10 to 95% RH / 
700-1060 hPa
Approximately 114g without batteries
Approximately 70 (w) mm × 70 (h) mm × 21 (d) mm
without the wrist cuff
Approximately 13.5 to 21.5 cm

Nylon and polyester
Main unit, storage case, battery set, instruction 
manual, guarantee card, blood pressure pass

= Type B

• This device fulfils the provisions of EC directive 93/42/EEC (Medical Device 

Directive). 

• This blood pressure monitor is designed according to the European Standard 

EN1060, Non-invasive sphygmomanometers Part 1: General Requirements 
and Part 3: Supplementary requirements for electromechanical blood 
pressure measuring systems.

• This OMRON product is produced under the strict quality system of OMRON 

HEALTHCARE Co. Ltd., Japan. The Core component for OMRON blood 
pressure monitors, which is the Pressure Sensor, is produced in Japan.

This marking shown on the product or its literature, indicates that it 
should not be disposed of, with other household wastes at the end 
of its working life. To prevent possible harm to the environment or 
human health from uncontrolled waste disposal, please separate 
this from other types of wastes and recycle it responsibly to 
promote the sustainable reuse of material resources.

Household users should contact either the retailer where they purchased this 
product, or their local government office, for details of where and how they can 
take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions 
of the purchase contract. This product should not be mixed with other commercial 
wastes for disposal. 

This product does not contain any hazardous substances.

Correct Disposal of This Product 
(Waste Electrical & Electronic Equipment)

IM-HEM-6052-RU-05-10/2011

5329896-0D

ulna

1.

2.

Push the      button.

Push the       button to confirm your choice and move 
onto the next step.

2.

2.

3.

1.

1.

Push the      button to toggle between “     ” (Left) 
and “     ” (Right).

      : Taking a reading on the left wrist.

      : Taking a reading on the right wrist.

Push the      button to choose which mode of the buzzer 
you wish to have.

If the Positioning indicator is “on1” or “on2”:

on1

: The buzzer sounds only when the monitor is in proper position.

on2

: The buzzer sounds a series of two short blips if your wrist is too 

far away from the measuring position, and sounds slowly when 
your wrist is in proper position.

oFF

: The buzzer will not sound.

If the Positioning indicator is “oFF”:

on

: The buzzer sounds when pressing any buttons.

oFF

: The buzzer will not sound.

Push the      button to confirm.

Blue light will flash.

Press the O/I START button to save settings and turn the 
monitor off.

The positioning indicator is set “on1”, the wrist for measurement is set “      ”, 
and the buzzer is set “on1” as default.
To reset to the default setting, press and hold down the SET button while in the 
setting mode, then press the O/I START button simultaneously for more than 2 
seconds.

User A

User B

The orange light

The wrist cuff will start to inflate automatically.

The blue light

Lower than
the heart.

Higher than
the heart.

Far away
from the
heart.

Keep at the
center of
the chest.

START

INFLATE

DEFLATE

COMPLETE

Alternating 

date/time display

4.   Troubleshooting and Maintenance

4.1   The Icons and Error Messages

Error Display

Cause

Remedy

Irregular or weak pulses 
are detected.

Movement during 
measurement.

The batteries are low. 

The batteries are 
exhausted. 

The posture has 
changed during
measurement.

Remove the wrist cuff. Wait 
2-3 minutes and then take 
another measurement. 
Repeat the steps in section 
3.3. If this error continues to 
appear, contact your doctor.

Carefully read and repeat the 
steps in section 3.3.

You should replace them with 
new ones ahead of time.
Refer to section 2.1.

You should replace them with 
new ones at once.
Refer to section 2.1.

Carefully read and repeat the 
steps listed under section 3.3.

Cuff is over inflated.

The wrist cuff is not 
wrapped securely.

Carefully read and repeat the 
steps listed under section 3.1.

Do not change the user ID 
during measurement.

The user ID has 
changed during
measurement.

Carefully read and repeat the 
steps listed under section 3.3.

An Er mark with a 
code/number indicates 
the device has a 
hardware failure.

Consult your OMRON
retail outlet or distributor.

Blink

Lit 

User A

User B

4.2   Troubleshooting

Problem

Cause

Remedy

The reading is 
extremely low (or 
high).

The wrist cuff is not at 
heart level.

The cuff is not 
wrapped snugly 
around the wrist.

Your arms and 
shoulders are tense.

Movement or talking 
during measurement.

Measure while in the 
correct posture. Refer 
to section 3.2.

Wrap the cuff correctly. 
Refer to section 3.1.

Relax and try taking the 
measurement again. 
Refer to section 3.3.

Wrist cuff pressure 
does not rise.

Air is leaking from the 
wrist cuff.

Consult your OMRON 
retail outlet or 
distributor.

Wrist cuff deflates too 
soon.

The wrist cuff is 
loose.

Apply the cuff correctly 
so that it is securely 
wrapped around the 
wrist. Refer to section 
3.1.

Remain still and do not 
talk during 
measurement. Refer to 
section 3.3.

Problem

Cause

Remedy

The unit loses power 
during measurement.

Nothing happens 
when you press the 
buttons.

The batteries are 
exhausted.

Replace the batteries 
with new ones.

The batteries are 
exhausted.

Replace the batteries 
with new ones.

The batteries have 
been inserted 
incorrectly.

Insert the batteries with 
the correct (+/-) polarity.

Other problems.

• Press the O/I START button and repeat 

measurement.

• If the problem continues, try replacing the 

batteries with new ones.

If this still does not solve the problem, contact 
your OMRON retail outlet or distributor.

The blood pressure is different each time. 
The reading is extremely low (or high).

Blood pressure readings 
constantly vary with time 
of day and how relaxed 
you are. Take several 
deep breaths and try to 
remain relaxed before 
taking a measurement.

Important information regarding Electro Magnetic Compatibility (EMC)

With the increased number of electronic devices such as PC’s and mobile 
(cellular) telephones, medical devices in use may be susceptible to 
electromagnetic interference from other devices. Electromagnetic interference 
may result in incorrect operation of the medical device and create a potentially 
unsafe situation.
Medical devices should also not interfere with other devices.

In order to regulate the requirements for EMC (Electro Magnetic Compatibility) 
with the aim to prevent unsafe product situations, the EN60601-1-2:2007 
standard has been implemented. This standard defines the levels of immunity to 
electromagnetic interferences as well as maximum levels of electromagnetic 
emissions for medical devices.

This medical device manufactured by OMRON HEALTHCARE conforms to this 
EN60601-1-2:2007 standard for both immunity and emissions.
Nevertheless, special precautions need to be observed:
• Do not use mobile (cellular) telephones and other devices, which generate 

strong electrical or electromagnetic fields, near the medical device. This may 
result in incorrect operation of the unit and create a potentially unsafe situation. 
Recommendation is to keep a minimum distance of 7 m. Verify correct operation 
of the device in case the distance is shorter.

Further documentation in accordance with EN60601-1-2:2007 is available at OMRON 
HEALTHCARE EUROPE at the address mentioned in this instruction manual.
Documentation is also available at www.omron-healthcare.com.

Made in China

Manufacturer

OMRON HEALTHCARE Co., Ltd.

53, Kunotsubo, Terado-cho, Muko, Kyoto,
617-0002 JAPAN

OMRON HEALTHCARE EUROPE B.V.

Scorpius 33, 2132 LR Hoofddorp 
THE NETHERLANDS
www.omron-healthcare.com

ComplectService Ltd.

13-14 building, 26 B. Tishinskiy per. 
Moscow 123557, RUSSIA
www.csmedica.ru

OMRON (DALIAN) CO., LTD.

Dalian, CHINA

EU-representative

Production Facility

Exclusive
distributor in
Russia & importer

12K2607

12

Что удобнее для чтения книг?

Планшет
Электронная книга
Смартфон
Книга в бумажном переплёте
Не читаю книг

QR код manualbase.ru
©  2010- ManualBase.ru